Icon New game New game

Building Construction Types Y/N Game

Yes or No

(7)
Test your knowledge of building construction types and fire protection measures with this quiz game. Determine whether the statements are true or false based on the information provided.

Download the paper version to play

Recommended age: 16 years old
129 times made

Created by

United States

Top 10 results

  1. 1
    Vincent Lovato
    Vincent Lovato
    01:19
    time
    100
    score
Do you want to stay in the Top 10 of this game? to identify yourself.
Make your own free game from our game creator
Compete against your friends to see who gets the best score in this game

Top Games

  1. time
    score
  1. time
    score
time
score
time
score
 
game-icon

Building Construction Types Y/N GameOnline version

Test your knowledge of building construction types and fire protection measures with this quiz game. Determine whether the statements are true or false based on the information provided.

by Suzanne Freeman
1

Type III Construction has interior building elements of any material permitted.

2

Type IV Construction has interior building elements of solid or laminated wood without concealed spaces.

3

Type V Construction has building elements that are limited to only wood.

4

Sprinkled buildings do not require maintenance of the fire sprinkler system.

5

Type IV Construction has exterior walls of laminated wood.

6

Type I Construction has exterior walls of noncombustible materials.

7

A building with a fire sprinkler system is considered Sprinkled.

8

Type III Construction has exterior walls of noncombustible materials.

9

Type V Construction has building elements that are of any materials permitted.

10

Type II Construction has building elements that are noncombustible.

11

Unprotected structural members are fire resistant according to their natural ability.

12

Type IV Construction has exterior walls of noncombustible materials.

13

Type V Construction has exterior walls of noncombustible materials.

14

Unsprinkled buildings are not protected by a fire sprinkler system.

15

Type II Construction has building elements that are combustible.

16

A building with a fire sprinkler system is considered Unsprinkled.

17

Protected structural members extend the fire resistance rating by at least 1 hour.

18

Type I Construction has building elements that are noncombustible.

19

Protected structural members have an additional fire rated coating.

20

Unprotected structural members have no additional fire rated coating.

educaplay suscripción